РУС|ENG
  • Products
    • Solenoid gas valves
    • Gas filters
    • Motorized gas valves
    • Pressure regulators-stabilizers
    • Safety shut-off valves
    • Safety relief valves
    • Pressure switches
    • Gas valves block units
    • Gas mixers
    • Leak-tightness control units
  • About us
    • TermoBrest Today
    • Production
    • Quality policy
    • Production line
    • Employees
    • Sales geography and dealer's system
    • We are trusted
    • Production of TermoBrest in exploitation
    • History of TermoBrest
  • News
    • News
    • Video
  • Documents
    • CERTIFICATES CE
    • CERTIFICATES EAC
    • CERTIFICATES GasCert
    • CERTIFICATES for supplies
    • Quality management system
    • Order forms for production
    • Technical catalogues
    • Printed catalogue
  • Dealers network
    • Sales network
  • Contact us
Products
  • Solenoid gas valves
  • Gas filters
  • Motorized gas valves
  • Pressure regulators-stabilizers
  • Safety shut-off valvesAluminium bodySteel body
  • Safety relief valves
  • Pressure switches
  • Gas valves block units
  • Gas mixers
  • Leak-tightness control units
  • New
Assistance:
Pressure loss calculationValve selection tool
Catalog menu
Homepage → Catalog → Safety shut-off valves → Steel body

Safety shut-off valves in steel body

FIELD OF APPLICATION CODE STRUCTURE
ASSISTANCE3D MODEL REQUEST
Filter
Info
  • Purpose
  • Structure
  • Pressure loss calculation
  • Valve selection tool
  • Assistance request
  • 3D MODEL REQUEST

Download PDF

Product catalogue Subscribe to our newsletter

JV «TermoBrest» Ltd.

Product catalogue Subscribe to our newsletter
Site development -
web design studio - Forever
Бресту 1000 лет
Feedback

Каталог продукции

  • Solenoid gas valves
  • Gas filters
  • Motorized gas valves
  • Pressure regulators-stabilizers
  • Safety shut-off valvesAluminium bodySteel body
  • Safety relief valves
  • Pressure switches
  • Gas valves block units
  • Gas mixers
  • Leak-tightness control units

CODE STRUCTURE

  1    2      3         4         5      6

ZК Х - Х - ХХХ - Х - Х

1. ZК — series.

2. Connection size, inches.
3. Maximum input pressure:
       1 — 1 бар;
       6 — 6 бар.
4. Three-unit code indicating actuation pressure range.
5. Climatic version:
       -30...+60 °С;
       -40...+60 °С.
6. Manufacturer’s declaration: ТУ BY 200020142.033-2013.

Depending on the connection size to the pipeline SSOV are manufactured:
coupling — from DN 15 up to DN 50;
flanged — from DN 15 up to DN 200.

Flanges of the safety relief valves comply with GOST 33259-2015, type 01, PN 6.

FIELD OF APPLICATION

Safety shut-off valve (SSOV) is designed for automatic cutoff of the gas supply to consumers in case of excess pressure above the set actuation limit.

FIELD OF APPLICATION AND OPERATING PRINCIPLE:

Safety shut-off valve is usually installed in gas distributing plants and installations in front of the pressure regulator-stabilizer and provides control of the outlet pressure received behind the regulator. The signal about the deviation of the gas pressure from the set value goes to SSOV through the impulse tube connected to the gas pipeline of outlet pressure. The value of the controlled pressure is adjusted by regulating the spring in SSOV. When the pressure set value is exceeded behind the regulator, the safety shut-off valve closes and cuts off the gas supply in the pipeline. It is possible to open the valve only in manual mode after eliminating the cause of excess gas pressure above the controlled one.

Safety shut-off valves comply with ТУ BY 200020142.035-2013.

Pressure loss calculation


Р=1.83кПа

Подбор арматуры


Assistance

3D MODEL REQUEST

Leave feedback about our site

Mailing