Блоки электромагнитных клапанов в угловом исполнении

Solenoid safety gas valves block unit in angle version is a set of solenoid safety gas valves and other gas fittings unit assembled into a single gas train (gas filter, pressure regulator-stabilizer, motorized gas valve, safety relief gas valve, safety shut-off gas valve, pressure switch, etc.).

In the units, the main safety valves and the gas filter are applied in an angle version.

Valve block units in angle version can be used at facilities where the circumstances are such that it would be difficult to assemble a linear block unit due to the face-to-face length. Furthermore, such units can be used in the process of design and development of measures aimed at restructuring of heat and power facilities, where the replacement of outdated gas train is required and the space is limited due to the existing gas pipeline supply, location of the boiler units and gas igniters.

TERMOBREST’s gas valve block units are suitable for any automated control system of boiler and burner equipment and can be used in the gas supply circuits for steam and hot water boilers of various types, including high-power boilers: PTVM, DKVR, DE and KVGM.

ADVANTAGES:

  • Shorter face-to-face length of a gas train;
  • Hydraulic resistance factor is 40% less compared with linear valve block units;
  • A variety of standard models, with the possibility of developing individual solutions for specific projects;
  • The use of TERMOBREST’s angle valve block units allow to significantly reduce the dimensions and consumption of gas pipeline valves of the burner, the number of welded joints, working hours for assembling and commissioning works, and to increase the operating reliability and length of service.

TECHNICAL SPECIFICATIONS for gas valve block units in angle version:

  • DN 40…200, flanged connection;
  • Рmax – 6 bar (0,6 МPа).

CLIMATIC VERSION:

  • (-30…+60 °С);
  • (-45…+60 °С);
  • (-60…+60 °С);
  • (-60…+60 °С);

AMBIENT TEMPERATURE:

  • -60…+70°С;
  • -45…+120 ˚С (special version);
  • -45…+90 °С (special version – is indicated in structure).

POWER SOURCE, V:

  • 220, 110, 24

AVERAGE LIFE:

  • 20 YEARS

-------------------------------------

If you need help selecting necessary equipment, please visit our web-site www.termobrest.ru or contact our specialists by e-mail info@termobrest.ru or by phone:

+375 (162) 53-64-13 (technical consultation line);

+375 (162) 53-64-76 (sales and logistics department).

GAS MIXERS

Gas mixer is applied for mixing fuel (gas) and air for optimal combustion process in gas engine or any other gas consumption device.

Combustion optimization process is aimed at increasing and improving the level of efficiency of gas combustion units and devices, as well as reducing the level of emissions.

FIELD OF APPLICATION:

Gas engines, gas engine generators, gas burners and other similar devices.

TYPE OF FUEL SUPPLY REGULATION:

Automatic regulation

Manual regulation

Fuel supply regulation is carried out in automatic mode by means of electric power drive or in manual mode.

Fuel supply is regulated by change of size of supply gas pipeline. Fuel in the mixer is sprayed through special holes located in the nozzle of the body and mixed with air to the required proportion.

FLOW RATE OF AIR (DEPEND ON SIZE OF MIXER HOUSING):

  • 90…650 ncm/h;
  • 250…1400 ncm/h;
  • 700…3000 ncm/h;
  • 2300…4800 ncm/h.

OPERATING MEDIUM TEMPERATURE:

  • -40 °С…+80 °С.

 

CLIMATIC VERSION:

  • -30…+60 °С;
  • -45…+60 °С;
  • -60…+60 °С.

 

Gas mixer can be installed both on horizontal and vertical sections of pipeline.

-------------------------------------

If you need help selecting necessary equipment, please visit our web-site www.termobrest.ru or contact our specialists by e-mail info@termobrest.ru or by phone:

+375 (162) 53-64-13 (technical consultation line);

+375 (162) 53-64-76 (sales and logistics department).