Motorized gas valve is designed as regulating device and is intended for usage in automatic remote-control systems of gas burning installations to control and safeguard streams of various gas mediums including natural gas, hydro-carbonated gases, gaseous phases of liquefied gas, compressed air and other non-aggressive gases.
Note! Motorized valve is not a shut-off device. It is designed and applied for smooth regulation of gas flow.
OPERATING PRESSURE
HOUSING VERSIONS (two types):
Type 1. Motorized regulating gas valve – a rotary cylinder serves as a working (regulating) member that provides the smooth change of the gas volume flow rate from 0.05% (in a closed position) up to 100% (in a fully opened position).
DIAMETER NOMINAL:
HOUSING MATERIAL:
OPERATING ENVIRONMENT TEMPERATURE:
Type 2. Butterfly-type-gas valve – a rotary throttle serves as a working (regulating) member that provides the smooth change of the gas volume flow rate from 0.5% (in a closed position) up to 100% (in a fully opened position).
DIAMETER NOMINAL:
HOUSING MATERIAL:
OPERATING ENVIRONMENT TEMPERATURE:
OPERATION MODE:
Power drive type
Manual type
In power drive type models, the flow rate control of the amount of passing gas through the motorized gas valve is controlled by the following types of actuators:
In manual type models, the flow rate control of the amount of passing gas is controlled by turning the control handle attached to the output end of the shaft. The scale shows: opening angle in degrees, arrows and signs "+" and "-". When turning the control handle towards the "+" sign, the amount of passing gas increases; when turning towards the "-" sign, the gas flow decreases.
The extreme control of handle positions, corresponding to the minimum and maximum gas flow rates, are limited by stops.
During operation, if necessary, the control handle can be dismantled and reinstalled.
REGULATION MODE (for power drive type models):
Proportional regulation. The following actuators are applied:
Proportional regulation. The following actuators are applied:
CLIMATIC VERSION:
MOUNTING POSITION:
VERSIONS:
General industrial usage
Explosion proof
Products in general industrial usage version are applied at all gas facilities where there are no special requirements to ensure the explosion safety of the electrical equipment;
Explosion-proof fitting units are applied at facilities and rooms where there are or may be formed explosive mixtures in the amount that requires special protection measures of the design, manufacture and operation of the electrical installations. To ensure safety in these zones the explosion-proof electrical equipment should be used.
Explosion-proof electrical equipment is the electrical equipment with such a construction as to eliminate the ignition of the surrounding explosive environment due to the operation of this electrical equipment.
-------------------------------------
If you need help to select necessary equipment, you should visit our web-site or contact our specialists by e-mail info@termobrest.ru or by phone:
+375 (162) 53-64-13 (technical consultation line);
+375 (162) 53-64-76 (sales and logistics department).
Safety shut-off gas valve is a device designed for automatic cutoff of the gas supply in case of pressure boost above requested actuation value.
FIELD OF APPLICATION and OPERATING PRINCIPLE:
Safety shut-off valve is usually installed in gas distributing plants and units in front of the pressure regulator-stabilizer and provides control of the output pressure received behind the regulator. The signal about the deviation of the gas pressure from the set value is sent to the safety shut-off valve through the impulse tube connected to the output pressure gas pipeline. The value of the monitored pressure is adjusted by regulating the spring in the safety shut-off valve. When the set value of pressure behind the regulator is exceeded, the safety shut-off valve closes and shuts off the gas supply in the pipeline. The valve can only be opened manually after eliminating the cause of gas pressure excess above the controlled one.
MAXIMUM INPUT PRESSURE:
ADJUSTMENT RANGE OF CONTROLLED PRESSURE:
Upon individual request: manufacture with different adjustment range.
DIAMETER NOMINAL and HOUSING VERSION:
Coupling DN 15÷50
Flange DN 15÷200
HOUSING MATERIAL:
CLIMATIC VERSION:
AMBIENT TEMPERATURE:
-------------------------------------
If you need help selecting necessary equipment, please visit our web-site www.termobrest.ru or contact our specialists by e-mail info@termobrest.ru or by phone:
+375 (162) 53-64-13 (technical consultation line);
+375 (162) 53-64-76 (sales and logistics department).