SAFETY RELIEF VALVES

Safety relief valve is a device designed for output pressure depression by means of releasing gases into the atmosphere or into a low pressure system when the set limit of the controlled pressure is above the requested value. Safety relief valve ensures protection of gas equipment from damage and prevents emergencies.

FIELD OF APPLICATION:

Safety relief valve is installed usually on the relief line next to the pressure regulator and applied at gas distributing plants/units and other equivalent equipment and installations, which require maintenance of the constant value of gas flow rate pressure.

MAXIMUM OPERATING PRESSURE:

  • up to 6 bar.

DIAMETER NOMINAL AND HOUSING VERSION:

Coupling DN 15÷50

Flange DN 15÷50

HOUSING MATERIAL:

  • aluminum;
  • steel.

VERSION:

Safety relief valve can be equipped with the device of forced opening operation, by means of which valve can be opened in manual mode.

CLIMATIC VERSION:

  • -30…+60 °С;
  • -40…+60 °С.

OPREATING MEDIUM TEMPERATURE:

  • from -30 to +70 °С.

-------------------------------------

If you need help selecting necessary equipment, please visit our web-site www.termobrest.ru or contact our specialists by e-mail info@termobrest.ru or by phone:

+375 (162) 53-64-13 (technical consultation line);

+375 (162) 53-64-76 (sales and logistics department).

LEAK-TIGHTNESS CONTROL UNITS

Leak-tightness control unit is a device designed for automatic checking of the gas valves block units before ignition of the burner and ensures a safe start-up of the boiler.

It is used to control the leak-tightness of the gas train (gas valves block units) of industrial boiler burners and similar gas-burning devices.

HOUSING TYPE:

(fig. 1)

(fig. 2)

Figure 1 – housing version with IP41 protection degree for installation in a cabinet with mounting on a din-rail (СВР-1 series);

Figure 2 – version with IP54 protection degree with the possibility of outdoor installation under roof (СВР-2 series).

FUNCTIONALITY:

  • Possibility of time setting for testing the valves in the process of monitoring the leak-tightness of the gas block unit;
  • Interacts with various types of boiler control automation;
  • Information about the leak-tightness of the solenoid valves is displayed on the LED panel;
  • Provides control in manual or automatic modes;
  • Can be completed with one or two pressure switches (mechanical or electronic types).

MAIN TECHNICAL CHARACTERISTICS:

Power source 220 V, 50 Hz; 24 V DC
Maximum current through the contact relays 5 А
Maximum switched voltage by contacts 250 V
Testing time range 10…990 sec (кратно 10)
Interface with remote computer RS-485
Power consumption no more than 6 VA
Average service life 9 years
Climatic version -30…60 °С

-------------------------------------